Skip to content

Grouped DCC-EX Serial Command Reference

Reference guide for serial commands used by EX-CommandStations, shown in functional groups.

This list may not be complete

This list of commands is manually created and may lag behind the latest developments. Refer to the Full Command List for the up-to-date list of commands.

Deprecated Commands

Commands marked with ⚠️ are deprecated and may be removed in future versions. Use the recommended alternatives where available.

DCC-EX Serial Commands Overview

Click to expand
  • Serial commands are accepted as input from the USB serial connection or a TCP/IP connection.
  • Commands have a single case dependent character opcode and optionally parameters.
  • Keyword parameters are shown in upper case but may be entered in mixed case.
  • Value parameters are decimal numeric (unless otherwise noted)
  • Not all commands have a response, and broadcasts mean that not all responses come from the last commands that you have issued.
  • Commands entered like <JA> are actually read as <J A>, so <Ja> is also acceptable.
  • Commands that produce diagnostic information (which is intended for human reading rather than code) only write to the USB Serial output.
  • Commands that cause state changes (such as loco speeds, turnout position) cause broadcasts to all serial connections and, where appropriate, WiThrottle protocol connections.

DCC-EX Serial Commands are also referred to as Native DCC-EX Commands/Protocol or DCC-EX Native Commands/Protocol.

Refer to the WiThrottle VS Native Serial Protocol page for information on the differences to the WiThrottle protocol/commands.

Conventions Used for Command Descriptions

Click to expand
  • < and > - All DCC-EX commands are surrounded by these characters to indicate the beginning and end, these must always be included
  • First letter or number - These are called OPCODES, are case sensitive, and must be specified as directed, e.g. 1, c, or -
  • CAPITALISED words - These are parameters referred to as keywords, and should be specified as directed, e.g. MAIN (note these are not case sensitive, however capitalising makes them easier to distinguish from other parameters)
  • lowercase words - These are parameters that must be provided or are returned, with multiple parameters separated by a space " ", e.g. loco or «loco»
  • Quoted "text" - Text within quote marks "" are used as descriptions, and must include the quote characters, for example <JR id "name" "functions"> becomes <J R 10,"DC Loco 10","/////////////////////////////FQ490 Hz/FQ3400 Hz/FQ62500 Hz">
  • Square brackets [] - Parameters within square brackets [] are optional and may be omitted, and if specifying these parameters, do not include the square brackets themselves
  • | - Use of the | character means you need to provide one of the provided options only, for example <0|1 MAIN|PROG|JOIN> becomes either <0 MAIN> or <1 MAIN>
  • 0|1 DIRECTION: 1=forward, 0=reverse.

Common Elements / Parameters

Click to expand

The following are element / parameters that are common across multiple commands and are described here for ease of reference.

Parameter Description
cab or
loco
The short (1-127) or long (128-10293) address of the engine decoder.
(This has to be already programmed in the decoder.)
Note: DCC-EX commands do not distinguish between short and long DCC addresses, so you can use the same command format for both.
dir or
direction
One of
1=forward
0=reverse
tSpeed One of
0 = stop
1-127 speed (1=slowest, 127=fastest)
-1 for Emergency Stop
speedByte Speed in DCC speedstep format. This is an encoded (1-7 bits) byte.
The single value incorporates both speed and direction, with the following values:
- reverse - 2-127 = speed 1-126, 0 = stop, 1 = Emergency Stop
- forward - 130-255 = speed 1-126, 128 = stop, 129 = Emergency Stop
id The numeric ID (0-32767) assigned to an element to control.
ids are generally unique within the element type, but not across element types.
(NOTE: ids are shared between Turnouts/Points, Sensors and Outputs)
vpin Generally, the pin number of the physical input or output GPIO to receive information from or to control.
vpins are normally assigned to an id to use in subsequent commands.

For GPIOs on the microcontroller, this is the same as the pin number. For servo outputs and I/O expanders, it is the pin number defined for the HAL device (if present), for example 100-115 for servos attached to the first PCA9685 Servo Controller module, 200-215 for the second PCA9685 Servo Controller module, 300-315 for the first PCA9685 I/O Expander module, and 400-415 for the second PCA9685 I/O Expander module.

System Commands

Command Description Parameters Status
<#> Request number of simultaneously supported locos None Active
<!> Emergency stop all locos None Active
<!P> Emergency stop and PAUSE loco movement None Active
<!R> Resume after <!P> None Active
<s> Command station status None Active
<E> Store EEPROM None Active
<e> Clear EEPROM None Active

Power Control

Command Description Parameters Status
<1> Power ON all tracks None Active
<1 MAIN> Power on MAIN track None Active
<1 PROG> Power on PROG track None Active
<1 JOIN> JOIN prog track to MAIN and power None Active
<1 track> Power on given track track: Track identifier Active
<0> Power off all tracks None Active
<0 MAIN> Power off MAIN track None Active
<0 PROG> Power off PROG track None Active
<0 track> Power off given track track: Track identifier Active

Locomotive Control

Command Description Parameters Status
<t loco> Request loco status loco: Locomotive ID Active
<t loco tSpeed direction> Set throttle speed and direction loco: ID, tSpeed: 0-127, direction: 0/1 Active
<t ignore loco tSpeed direction> Set throttle speed and direction Legacy format ⚠️ Deprecated
<- loco> Remove loco state and reminders loco: Locomotive ID Active
<-> Clear loco state and reminder table None Active

Function Control

Command Description Parameters Status
<F loco function onoff> Set loco function ON/OFF loco: ID, function: Function number, onoff: 0/1 Active
<F loco DCCFREQ freqvalue> Set DC frequency for loco loco: ID, freqvalue: Frequency value Active
<f loco byte1> Set loco function group loco: ID, byte1: Function byte ⚠️ Deprecated
<f loco group byte2> Set loco function group loco: ID, group: Group ID, byte2: Function byte ⚠️ Deprecated

Consist Control

Command Description Parameters Status
<^> Show all consists none Active
<^ leadLoco follower [ follower2..7]> Create Consist loco: ID, negative for reversed loco Active
<^ loco> Deletes consist loco1: ID Active

Turnout/Point Control

Command Description Parameters Status
<T> List all turnouts/points None Active
<T id> Delete turnout/point id: Turnout ID Active
<T id X> List turnout/point details id: Turnout ID Active
<T id T> Throw turnout/point id: Turnout ID Active
<T id C> Close turnout/point id: Turnout ID Active
<T id value> Close (value=0) or Throw turnout id: Turnout ID, value: 0/1 Active
<T id SERVO vpin closedValue thrownValue> Create servo turnout id: ID, vpin: Pin, values for positions Active
<T id VPIN vpin> Create pin turnout id: ID, vpin: Pin number Active
<T id DCC addr subAddr> Create DCC turnout id: ID, addr: Address, subadd: Sub-address Active
<T id DCC linearAddr> Create DCC turnout id: ID, linearAddr: Linear address Active
<T id addr subadd> Create DCC turnout id: ID, addr: Address, subadd: Sub-address Active
<T id vpin closedValue thrownValue> Create SERVO turnout id: ID, vpin: Pin, position values Active

Sensor Control

Command Description Parameters Status
<S id vpin pullup> Create sensor id: Sensor ID, vpin: Pin, pullup: Pull-up setting Active
<S id> Delete sensor id: Sensor ID Active
<S> List sensors None Active
<Q> List all sensors None Active

CV Programming

Command Description Parameters Status
<W cv value> Write CV value on PROG track cv: CV number, value: Value Active
<W loco> Write loco address on PROG track loco: Address Active
<W CONSIST loco> Write consist address on PROG track loco: Address Active
<W CONSIST loco REVERSE> Write consist address and reverse flag loco: Address Active
<W cv bitvalue bit> Write CV bit on prog track cv: CV, bitvalue: Bit value, bit: Bit position Active
<W cv value ignore1 ignore2>ignore1 ignore2) Write CV value on PROG track Legacy format ⚠️ Deprecated
<R cv> Read CV cv: CV number Active
<R> Read driveable loco ID None Active
<R LOCOID> Read loco ID (ignoring consist) None Active
<R CONSIST> Read consist ID None Active
<R cv ignore1 ignore2> Read CV value on PROG track Legacy format ⚠️ Deprecated
<V cv value> Fast read CV with expected value cv: CV number, value: Expected value Active
<V cv bit bitvalue> Fast read bit with expected value cv: CV, bit: Bit position, bitvalue: Expected Active
<B cv bit bitvalue> Write CV bit cv: CV number, bit: Bit position, bitvalue: Value Active
<w loco cv value> POM write CV on main track loco: ID, cv: CV number, value: Value Active
<r loco cv> POM read CV on main track loco: ID, cv: CV number Railcom dependent
<b loco cv bit bitvalue> POM write CV bit on main track loco: ID, cv: CV, bit: Position, bitvalue: Value Active

DCC Accessory Commands

Command Description Parameters Status
<a address subaddress activate> Send DCC accessory command address: Address, subaddress: Sub-address, activate: 0/1 Active
<a address subaddress activate onoff> Send DCC accessory command with on/off address: Address, subaddress: Sub, activate: 0/1, onoff: 0/1 Active
<a linearaddress activate> Send DCC accessory command linearaddress: Linear address, activate: 0/1 Active
<A address value> Send DCC extended accessory (Aspect) command address: Address, value: Aspect value Active

Momentum Control

Command Description Parameters Status
<m LINEAR> Set momentum algorithm to linear acceleration None Active
<m POWER> Set momentum algorithm based on speed difference None Active
<m loco momentum> Set momentum for loco (accel and braking) loco: ID, momentum: Value Active
<m loco accelerating braking> Set momentum for loco loco: ID, accelerating: Value, braking: Value Active

Output Control

Command Description Parameters Status
<Z> List output definitions None Active
<Z id pin iflag> Create output id: Output ID, pin: Pin number, iflag: Invert flag Active
<Z id active> Set output id: Output ID, active: 0/1 Active
<Z id> Delete output id: Output ID Active

Pin Control

Command Description Parameters Status
<z vpin> Set pin HIGH if vpin positive, LOW if negative vpin: Pin number (signed) Active
<z vpin analog> Write analog device value vpin: Pin, analog: Value Active
<z vpin analog profile> Write analog device using profile vpin: Pin, analog: Value, profile: Profile ID Active
<z vpin analog profile duration> Change analog value over duration vpin: Pin, analog: Value, profile: Profile, duration: Time Active

NeoPixel Control

Command Description Parameters Status
<o vpin> Set neopixel on (vpin>0) or off (vpin<0) vpin: Pin number (signed) Active
<o vpin count> Set multiple neopixels on/off vpin: Pin, count: Number of pixels Active
<o vpin r g b> Set neopixel colour vpin: Pin, r: Red, g: Green, b: Blue Active
<o vpin r g b count> Set multiple neopixels colour vpin: Pin, r: Red, g: Green, b: Blue, count: Count Active

Turntable Control

Command Description Parameters Status
<I> List all turntables None Active
<I id> Broadcast turntable type and current position id: Turntable ID Active
<I id position> Rotate a DCC turntable id: ID, position: Position Active
<I id DCC home> Create DCC turntable id: ID, home: Home position Active
<I id position activity> Rotate an EXTT turntable id: ID, position: Position, activity: Activity Active
<I id EXTT vpin home> Create an EXTT turntable id: ID, vpin: Pin, home: Home position Active
<I id ADD position value angle> Add turntable position id: ID, position: Position, value: Value, angle: Angle Active

Sound Control

Command Description Parameters Status
<y vpin PLAY track [volume]> Play track Active
<y vpin REPEAT track [volume]> Play track repeat Active
<y vpin STOP> Stop playing Active
<y vpin PAUSE> Pause playing Active
<y vpin RESUME> Resume playing Active
<y vpin FOLDER folder> Set folder to play from Active
<y vpin VOLUME vol> Set default volume 0..30 Active
<y vpin EQ type> Set EQ type NORMAL, POP, ROCK, JAZZ, CLASSCS, BASS Active
<y vpin RESET> Reset player Active

Throttle Information Commands

Command Description Parameters Status
<J M> List stash values None Active
<J M stashId> Get stash value stash_id: Stash identifier Active
<J M CLEAR ALL> Clear all stash values None Active
<J M CLEAR stashId> Clear given stash stash_id: Stash identifier Active
<J M stashId locoId> Set stash value stashId: Stash ID, locoId: Loco ID Active
<J M CLEAR ANY locoId> Clear all stash entries containing locoId locoId: Locomotive ID Active
<J C> Get fastclock time None Active
<J C mmmm nn> Set fastclock time mmmm: Minutes, nn: Rate Active
<J G> Report gauge limits None Active
<J I> Report currents None Active
<J A> List routes None Active
<J R> List roster None Active
<J R id> Get roster for loco id: Locomotive ID Active
<J T> Get turnout/point list None Active
<J T id> Get turnout state and description id: Turnout ID Active
<J O> List turntable IDs None Active
<J O id> List turntable state id: Turntable ID Active
<J P id> List turntable positions id: Turntable ID Active

Track Manager

Command Description Parameters Status
<=> List track manager states None Active
<= track MAIN> Set track to MAIN track: Track identifier Active
<= track MAIN_INV> Set track to MAIN inverted polarity track: Track identifier Active
<= track MAIN_AUTO> Set track to MAIN with auto reversing track: Track identifier Active
<= track PROG> Set track to PROG track: Track identifier Active
<= track OFF> Set track power OFF track: Track identifier Active
<= track NONE> Set track no output track: Track identifier Active
[<= track EXT>](?_▫equals▫_▫track▫_▪EXT▪) Set track to use external sync track: Track identifier Active
<= track AUTO> Update track to auto reverse track: Track identifier Active
<= track INV> Update track to inverse polarity track: Track identifier Active
<= track DC loco> Set track to DC track: Track ID, loco: Loco ID Active
<= track DC_INV loco> Set track to DC with inverted polarity track: Track ID, loco: Loco ID Active
<= track DCX loco> Set track to DC with inverted polarity. Same as DC_INV track: Track ID, loco: Loco ID Active

Configuration Commands

Command Description Parameters Status
<C PROGBOOST> Configure PROG track boost None Active
<C RESET> Reset and restart EX-CommandStation None Active
<C SPEED28> Set all DCC speed commands as 28 step None Active
<C SPEED128> Set all DCC speed commands to 128 step (default) None Active
<C RAILCOM onOff> Enable/Disable Railcom cutout None Active
<C RAILCOM DEBUG> Enable Railcom cutout for scope testing None Active
<C WIFI "ssid" "password"> Reconfigure stored STA WiFi credentials ssid: Network name, password: Password Active
<C WIFI AP "ssid" "password" [channel]> Reconfigure stored WiFi AP ssid: Network name, password: Password Active
<C WIFI HIDDENAP "ssid" "password" [channel]> Reconfigure stored WiFi AP ssid: Network name, password: Password Active
<C WIFI DEFAULT> Set WiFi to default None Active
<C WIFI onOff> Set WiFi on/off name None Active

Diagnostic Commands

Command Description Parameters Status
<D ACK onoff> Enable/Disable PROG track diagnostics None Active
<D ACK LIMIT value> Set ACK detection limit mA value: Current limit in mA Active
<D ACK MIN value MS> Set ACK minimum duration mS value: Duration in milliseconds Active
<D ACK MIN value> Set ACK minimum duration µS value: Duration in microseconds Active
<D ACK MAX value MS> Set ACK maximum duration mS value: Duration in milliseconds Active
<D ACK MAX value> Set ACK maximum duration µS value: Duration in microseconds Active
<D ACK RETRY value> Set ACK retry count value: Retry count Active
<D CABS> Diagnostic display loco state table None Active
<D RAM> Diagnostic display free RAM None Active
<D CMD onOff> Enable/Disable command input diagnostics None Active
<D RAILCOM onOff> Enable/Disable Railcom diagnostics None Active
<D WIFI onOff> Enable/Disable WiFi diagnostics None Active
<D WIFI SHOW> Shows WiFi settings None Active
<D ETHERNET onOff> Enable/Disable Ethernet diagnostics None Active
<D WIT onOff> Enable/Disable Withrottle diagnostics None Active
<D LCN onOff> Enable/Disable LCN diagnostics None Active
<D WEBSOCKET onOff> Enable/Disable Websocket diagnostics None Active
<D EEPROM numentries> Dump EEPROM contents numentries: Number of entries Active
<D ANOUT vpin position> Test analog output ⚠️ Deprecated - use <z vpin position> vpin: Pin, position: Position Active
<D ANOUT vpin position profile> Test analog output with profile ⚠️ Deprecated - use <z vpin position profile> vpin: Pin, position: Position, profile: Profile Active
<D SERVO vpin position> Test servo vpin: Pin, position: Position Active
<D SERVO vpin position profile> Test servo with profile vpin: Pin, position: Position, profile: Profile Active
<D ANIN vpin> Display analogue input value vpin: Pin number Active
<D HAL SHOW> Show HAL devices table None Active
<D HAL RESET> Reset all HAL devices None Active
<D TT vpin steps> Test turntable vpin: Pin, steps: Step count Active
<D TT vpin steps activity> Test turntable with activity vpin: Pin, steps: Steps, activity: Activity Active

Raw DCC Packets

Command Description Parameters Status
<M ignore d0 d1 d2 d3 d4 d5> Send up to 5 byte DCC packet on MAIN track ignore: Ignored, d0-d5: Hex bytes Active
<P ignore d0 d1 d2 d3 d4 d5> Send up to 5 byte DCC packet on PROG track ignore: Ignored, d0-d5: Hex bytes Active
<c> Report main track current None ⚠️ Deprecated

Signal Commands

TODO LOW - Signal Commands

Reserve/Block Commands

TODO LOW - Reserve/Block Commands

Automation Commands

TODO LOW - Automation Commands

WiFI and Ethernet Commands

TODO LOW - WiFi and EthernetCommands