<J C [«mmmm» [«nn»]]>
Get/Set the Fastclock Time¶
Serial commands to get or set the Fastclock time.
Command(s)¶
<J C [«mmmm» [«nn»]]>Set fastclock time<J C>get fastclock time
Parameters¶
- mmmm: minutes (hours * 60)
-
nn: speed factor. Default is 1
-
parameter: Required|optional description - one of:
option= explanation of optionoption= explanation of option- ...
-
...
Response¶
J C [«mmmm»>
Notes¶
- None
Examples¶
Also see the EXRAIL Time Control Cookbooks.
Example Commands¶
- Set the time to 6:25 with a speed factor of 4:
<J C 375 4> - Request the current time:
<J C>
Example Responses:¶
- Response to
<JC 375 4>:<jC 375> - Response to
<JC>if the current time is 6:15 :<jC 375>